Instructions for use and notes of the plunger tip
1. The sprue bushing and the shot sleeve should be correctly axially fit witheach other; otherwise they will result in the unilateral tensioned damage and unilateral wearing of the plunger tip;
2. Preheat the plungertip beforeusing, because it can eliminate the gap between the shot sleeve and sprue bushing, so as to avoid the strainof the plunger tip. Shot several modes slowly on the plungertip when opening the machine. it can also make the gap betweeniniection and solution cup idealized.
3. The mechanical properties of the plungertip willlost at high temperature, and the water cycle cooling can be used as much as possible to extend the service life of the plunger tip.
4. Although the graphite in nodular castiron presents pellets which have oillubrication function, the spherical graphite is extremely small. The suggestion is that theusers should use low molecular weight lubricating oil to extend the service life of the plunger tip.
5. The user should roughly determine the tolerance coefficient of the plunger according to the sizes of the plunger, cooling conditions and the shot sleeve conditions. The tolerance coefficient isusually selected form 0.10% to 0.17% to calculate the tolerance of the plunger.
Standard Plunger Head
Diamter: 40mm/50mm/60mm/70mm/80mm/90mm/100mm/110mm/120mm/130mm/140mm/150mm/160mm/170mm/180mm/190mm/200mm
Custom Plunger Head
Diamter: 45mm/55mm/65mm/75mm/85mm/95mm/105mm/115mm/125mm/135mm/145mm/155mm/165mm/175mm/185mm/195mm/205mm
Besides the standard,also we can supply the special plunger head according to your requirement.
Standard Plunger head/Plunger tip specification list | |||
Model ΦA | Length mm |
Screw thread M |
Shoulder Area ΦDXH |
Φ40 | 80/90 | M27X2 | Φ30XH12 |
Φ50 | 80/90 | M27X2 | Φ30XH12 |
M30X2 | Φ35XH12 | ||
Φ60 | 80/90 | M30X2 | Φ35XH12 |
M33X2 | Φ38XH15 | ||
M36X2 | Φ40XH15 | ||
Φ70 | 90/100/120 | M30X2 | Φ35XH12 |
M33X2 | Φ38XH15 | ||
M36X2 | Φ40XH15 | ||
Φ80 | 90/100/120 | M36X2 | Φ40XH15 |
M42X2 | Φ45XH15 | ||
Φ90 | 90/100/120 | M36X2 | Φ40XH15 |
M42X2 | Φ45XH15 | ||
Φ100 | 90/100/120 | M36X2 | Φ40XH15 |
M42X2 | Φ45XH15 | ||
Φ110 | 120/140 | M42X2 | Φ45XH15 |
M52X2 | Φ55XH15 | ||
Φ150 | 200 | M56X3 | Φ60XH30 |